Laboratory sorting machines | VOMET

We value your privacy.

Our company and our partners store or access information on devices, such as cookies, and process personal data, such as unique identifiers and standard information that the device sends for the purposes described below.

We use cookies mainly to anonymously analyze traffic and improve our websites. If you set your browser to block cookies, some parts of this website may not function properly or the website may slow down.

You can provide consent to the above processing by clicking the “Accept All” button. Or you can refuse to provide it by clicking the “Reject All” button. You can change your preferences by clicking the “Manage Settings” button.

Your preferences will only apply to this website. We do not need your consent for some forms of processing of your personal data.

You can change your preferences at any time by returning to this page or by clicking the “Manage Cookies” link in the footer. You can find more information about cookie processing on this page.

Laboratory sorting machines

Complete solutions for laboratory analysis

In the laboratory program segment, you will find equipment necessary for laboratory sieve analysis of particle size (so-called grain size control). These include analytical sieves, laboratory sieving machines (otherwise called sieve shakers or shakers), analytical and precision balances, drying ovens, ultrasonic sieve cleaners, dividers (so-called quarterers), shape index meters and devices for photo-optical particle analysis.

Laboratory sorting machines

LABORATORY SCREENS

Circular screens

With diameters of 100, 200, 300, 400 mm; we can also supply screens whose diameter is given in English inches, but we do not recommend combining them with screens manufactured in millimeter diameters (deviations).

Square screens

In a beech frame with dimensions of 500 × 500 mm or 300 × 300 mm.

Screens for alpine sorting machines

Old and new generation (diameter 200 or 203 mm).

Certification

Screens are normally supplied with a sales protocol, in which the manufacturer confirms that the technical fabric inserted into the frame has been measured and approved; upon request, we can provide verification or calibration (not included in the basic price of the screen).

The sieves are manufactured according to DIN ISO 3310.

LABORATORY SORTING MACHINES

Laboratory analytical sorting machines (sieving machines) are used for the automatic sorting of bulk materials into individual fractions. They enable regular analysis results to be obtained in a very short time. The sorting process simulates manual sieving as the basis of the entire separation technique.

NEXOPART laboratory machines create a three-dimensional sieving movement, stratifying the sorted material over the entire surface of the sieve. For materials that are difficult to sift, the process can be programmed to be interrupted, which intensifies the sieving. This speeds up the entire process.

NEXOPART analytical sieve shakers with electromagnetic drive have no rotating parts, are very robust, do not require regular maintenance, and are minimally noisy. They have a double spring system, and the use of cast iron parts makes their construction solid. No unwanted vibrations are transmitted to the fixed parts of the analytical sieve shaker and its base. They have versatile uses.

NEXOPART EML 200 DIGITAL PLUS

T - for dry sorting; N - for wet sorting

  1. for analytical sieves with diameters of 3" (76.2 mm), 100 mm, 150 mm, 200 mm, 8" (203 mm)
  2. programmable, memory functions
  3. computer-controlled
  4. three-dimensional sieve movement
  5. full electronic control
  6. digital displays for all functions
  7. maximum weight of the controlled sample: 3 kg

Technical data

Mains voltage: 230 V, 50 or 60 Hz (110 V, 60 Hz).
Amplitude: adjustable (PLUS type), max. approx. 3 mm.
Timer: 0-99 minutes or continuous operation.
Weight: approx. 34 kg.

The EML 200 analytical sieve shakers can be equipped with guide bars of different lengths (620, 445, 560 or 660 mm). The number of sieves clamped in the machine (8, 5, 7, 9) with a height of 50 mm depends on the length of the bars. The 660 mm long bars are designed for the EASY LOCK clamping system.

For optimal operation, they can be placed in a soundproof box.

We also supply these laboratory machines in a version without adjustable amplitude and computer control (NEXOPART EML 200 digital T and N).

NEXOPART EML 300/315 DIGITAL PLUS

T - for dry sorting; N - for wet sorting

  1. for analytical sieves with diameters of 200 mm, 8 "(203mm), 250 mm, 300 mm, 305 mm
  2. programmable, memory functions
  3. computer-controlled
  4. three-dimensional sieve movement
  5. full electronic control
  6. digital displays for all functions
  7. max. weight of the controlled sample: 6 kg

Technical data

Mains voltage: 230 V, 50 or 60 Hz (110 V, 60 Hz).
Amplitude: adjustable, max. approx. 2 mm.
Timer: 0-99 minutes or continuous operation.
Weight: approx. 38 kg.

The EML 300/315 analytical sieve shakers can be equipped with guide bars of different lengths (620, 445, 560 or 660 mm). The number of sieves clamped in the machine (7, 4, 6 or 8) with a height of 60 mm depends on the length of the bars. The bars with a length of 660 mm are designed for the EASY LOCK clamping system.

For optimal operation, they can be placed in a soundproof box.

1 / 2

NEXOPART EML 450 DIGITAL PLUS T with clamping system Classic

T - for dry sorting; N - for wet sorting

  1. for analytical sieves with diameters of 200 mm, 8 "(203mm), 250 mm, 300 mm, 305 mm, 450 mm
  2. programmable, memory functions
  3. computer-controlled
  4. three-dimensional sieve movement
  5. full electronic control
  6. digital displays for all functions
  7. max. weight of the controlled sample: 15 kg

Technical data

Mains voltage: 230 V, 50 or 60 Hz (110 V, 60 Hz).
Amplitude: adjustable, max. approx. 1.5 mm.
Timer: 0-99 minutes or continuous operation.
Weight: approx. 42 kg.

The EML 300/315 analytical sieve shakers can be equipped with guide bars of different lengths (620, 445, 560 or 660 mm). The number of sieves clamped in the machine (7, 4, 6 or 8) with a height of 60 mm depends on the length of the bars.

For optimal operation, they can be placed in a soundproof box.


NEXOPART UWL 400

Extremely powerful and quiet, T - for dry sorting; N - for wet sorting.

  1. for analytical sieves with diameters of 200 mm, 8" (203 mm), 300 mm, 315 mm, 350 mm, 400 mm
  2. three-dimensional sieve movement
  3. max. weight of the inspected sample: 20 kg

Technical data

Mains voltage: 400 V AC, 50 Hz.
Timer: 0-60 minutes or continuous operation.
Weight: approx. 190 kg.

The UWL 400 analytical sieve shakers, as the most powerful machines in the NEXOPART series, have the best conditions for efficient and error-free sorting. These machines are used primarily for coarse-grained materials. In the standard version, they can accommodate 8 to 10 analytical sieves with a height of 65 mm (guide rods with a length of 850 and 1000 mm, for EASY LOCK rods 900 mm). The UWL 400 laboratory machines for dry sorting can be supplied in the UWL 400 H version for square sieves with a wooden frame (300x300 mm or 500x500 mm) or in the UWL 400 Ex version for sorting hazardous substances in explosive environments.

For optimal operation, the machine can be placed in a soundproof box.


TYLER RO-TAP

These analytical sieve shakers replicate the circular and tapping motion of manual sieving with a uniform mechanical motion to ensure reliable and comparable analyses. The machine is driven by an electric motor via a worm gear. All machines comply with CE directives.

Technical data

Digital timer: 0-99 min.
Mains voltage: 230 V, 50 Hz or (110 V, 60 Hz).
RPM: 285 ± 10.
Knock pulses: 150 ± 10.
Weight: approx. 82 kg.
Dimensions: 710 x 530 x 635 mm.

For optimal operation, the machine can be placed in a soundproof box.

TYLER RO-TAP ® 12" RX-30

  1. for analytical sieves with a diameter of 12" (305mm) or 300 mm
  2. designed for 6 analytical sieves with a height of 50 mm or 13 sieves with a height of 25 mm plus a sieve pan

TYLER RO-TAP ® II- RX-94

  1. for analytical sieves with a diameter of 8" (203mm) or 200 mm
  2. designed for 2 sets of 6 analytical sieves with a height of 50 mm or 13 sieves with a height of 25 mm (plus sieve pan)
  3. dimensions: 780x780x750 mm
  4. weight: approx. 100 kg

TYLER 8" RX-86

  1. for analytical sieves with a diameter of 8" (203mm) or 200 mm
  2. designed for 6 analytical sieves with a height of 50 mm or 13 sieves with a height of 25 mm plus a sieve pan.
  3. Due to the low weight of the machine (28 kg), this sieve can be used as a portable inspection machine
  4. This product is designed for sorting materials that are thicker than 300 µm.
  5. horizontal sieving movement without impact

TYLER RO-TAP ® 8" RX-29, MODEL B-DIN ISO 9284

  1. for analytical sieves with a diameter of 8" (203 mm) or 200 mm
  2. designed for 6 analytical sieves with a height of 50 mm or 13 analytical sieves with a height of 25 mm plus a sieve pan


CLAMPING SYSTEM FOR LABORATORY MACHINES

EASYLOCK clamping system


TWIN NUT CLAMPING SYSTEM

LABORATORY ACCESSORIES

CLEANERS

Analytical sieve cleaning devices (ultrasonic cleaners)

NEXOPART USC 200

  1. cleaning of individual screens
  2. for analytical sieves up to an outer diameter of 230 mm
  3. timer 0-15 min or continuous operation
  4. high-frequency continuous peak power 2x240 W/period, 35 kHz
  5. mains voltage230 V
  6. frequency regulation 50 - 60 Hz


NEXOPART USC 500

  1. cleaning of individual screens
  2. for analytical sieves up to an outer diameter of 500 mm
  3. timer 0-15 min or continuous operation
  4. high-frequency continuous peak power: 2x600 W/period, 35 kHz
  5. mains voltage 230 V
  6. frequency regulation 50-60 Hz

NEXOPART USC 200 MULTI

  1. for simultaneous vertical cleaning of up to 5 analytical sieves with a diameter of 200 or 203 mm
  2. timer 0-15 min or continuous operation
  3. high-frequency continuous peak power 2x1000 W/period, 35 kHz
  4. mains voltage 230 V
  5. frequency regulation 50-60 Hz

DIVIDER

A sample divider (quarterer) is used to divide the materials into representative test samples. In the dividing head, the material is evenly distributed into collecting cups.

NEXOPART RT 6.3 - RT 12.5

The divider consists of a stand made of painted steel sheet, three collecting trays made of tinplate or plastic-coated sheet metal and a dividing head made of stainless steel sheet metal. It is supplied with sorting slots according to the size of the divided material.

RT 6.3: 12 grooves ( 6.3 mm = 1 " )
RT 12.5: 18 grooves ( 12.5 mm = 1 " )

For cutting fine material, it can be supplied with a dust cover.

NEXOPART RT 25 - RT 37.5 - RT 50 - RT 75

The divider consists of a stand, a dividing head and three collecting trays made of hot-dip galvanized steel sheet. It is supplied with sorting slots according to the size of the divided material.

RT 25: 16 grooves ( 25 mm = 1")
RT 37.5: 12 grooves ( 37.5 mm = 11")
RT 50: 8 grooves (50 mm = 2")
RT 75: 6 grooves (75 mm = 3")

CPA SOFTWARE

Computer program for evaluating sieve analyses

This software was developed for computer evaluation of sieve analyses according to valid standards. For entering basic data into the PC and after the sieving process, the individual analytical sieves with excess material are completely weighed. (The determined weights can be entered manually or are automatically transferred from the balance to the PC.) CpaServ SOFTWARE  evaluates sieve analyses. WE SUPPLY IN ENGLISH OR GERMAN VERSION.

Photo-optical analysis

NEXOPART- CPA

The NEXOPART - CPA device can be used to perform grain size and shape analyses. The device, built on glass fiber technology, measures dry and non-agglomerated bulk materials in the measurement range from 40 µm to 400 mm. The principle is similar to that of a fax machine, where a stream of particles is continuously scanned.

Compared to other optical measurement methods, it achieves a significantly larger measurement range and faster passage of the measured material. The digital CCD line camera processes over 20 million pixels and up to 4,000 particles per second at a resolution of up to 12 µm /pixel/. System performs more than 33,000 scans per second.

NEXOPART -CPA analysis provides grain shape values, particle count, information on particle circumference and surface area, grain distribution in arbitrary size classes and other parameters. Grain size analysis shows the grain size distribution as an undersized, oversized or density curve.

The results are displayed in a table or graphically. These devices can be operated down to -40°C, e.g. in the food industry. Online devices are used in a wide variety of industries. They are used for continuous optimization of production. All common interfaces are set.

Advice and consultations

How to choose the right product?
If you need advice, don't hesitate to ask! We will answer your questions and help you
with every step in the selection of materials and the implementation of projects.

  • we will provide technical information and documentation

  • we will advise on the correct selection and use of materials

  • we will provide a technical solution

  • consultations on the application and suitability of our products

Get in touch with our experts

Leave us a message, we will contact you

Form error icon
Form error icon
Form error icon
Form error icon
Form error icon
Form error icon
}